Location

2004/11/16 18:21:28 42.00N 120.45W 9 3.8 Oregon

Arrival Times (from USGS)

Arrival time list

Felt Map

USGS Felt map for this earthquake

USGS Felt reports page for Intermountain Western US

Focal Mechanism

The focal mechanism was determined using broadband seismic waveforms. The location of the event and the station distribution are given in Figure 1.
Figure 1. Location of broadband stations used to obtain focal mechanism


  NODAL PLANES 

  
  STK=     149.99
  DIP=      74.99
 RAKE=    -130.00
  
             OR
  
  STK=      42.85
  DIP=      42.27
 RAKE=     -22.64
 
 
DEPTH = 012.0 km
 
Mw = 3.95
Best Fit 0.8641 - P-T axis plot gives solutions with FIT greater than FIT90

Focal Mechanism

First motion data

The P-wave first motion data for focal mechanism studies are as follow:

Sta Az(deg)    Dist(km)   First motion
WDC       229  237 eP_X
BMN       122  322 eP_+
CMB       179  441 eP_X
TPH       147  516 eP_X

Surface-wave analysis

Surface wave analysis was performed using codes from Computer Programs in Seismology, specifically the multiple filter analysis program do_mft and the surface-wave radiation pattern search program srfgrd96.

The velocity model used for the search is a modified Utah model .

Data preparation

Digital data were collected, instrument response removed and traces converted to Z, R an T components. Multiple filter analysis was applied to the Z and T traces to obtain the Rayleigh- and Love-wave spectral amplitudes, respectively. These were input to the search program which examined all depths between 1 and 25 km and all possible mechanisms.
Best mechanism fit as a function of depth. The preferred depth is given above. Lower hemisphere projection

Pressure-tension axis trends. Since the surface-wave spectra search does not distinguish between P and T axes and since there is a 180 ambiguity in strike, all possible P and T axes are plotted. First motion data and waveforms will be used to select the preferred mechanism. The purpose of this plot is to provide an idea of the possible range of solutions. The P and T-axes for all mechanisms with goodness of fit greater than 0.9 FITMAX (above) are plotted here.


Focal mechanism sensitivity at the preferred depth. The red color indicates a very good fit to the Love and Rayleigh wave radiation patterns. Each solution is plotted as a vector at a given value of strike and dip with the angle of the vector representing the rake angle, measured, with respect to the upward vertical (N) in the figure. A nearly vertical strike-slip fault striking at 75 or 165 degrees is preferred. Because of the symmetry of the spectral amplitude rediation patterns, only strikes from 0-180 degrees are sampled.

Love-wave radiation patterns

Rayleigh-wave radiation patterns

Broadband station distributiuon

Sta Az(deg)    Dist(km)   
YBH	  262	  190
WDC	  229	  237
ORV	  198	  286
BMN	  122	  322
JCC	  247	  327
COR	  322	  369
HOPS	  214	  402
CMB	  179	  441
TPH	  147	  516
HLID	   69	  523
SAO	  189	  588
TPNV	  146	  667
OCWA	  336	  704
HWUT	   90	  739
NEW	   19	  743
MSO	   42	  745
AHID	   81	  774
MVU	  116	  800
BOZ	   57	  816
SHB	  344	  885
BW06	   81	  900
WALA	   31	  934
LLLB	  354	  963
LAO	   60	 1246
BBB	  336	 1271
ISCO	   96	 1272
EDM	   21	 1355
SDCO	  105	 1361
TUC	  138	 1374
DGMT	   55	 1461
MOBC	  329	 1510
CBKS	   94	 1789
ULM	   56	 2095

Waveform comparison for this mechanism

Since the analysis of the surface-wave radiation patterns uses only spectral amplitudes and because the surfave-wave radiation patterns have a 180 degree symmetry, each surface-wave solution consists of four possible focal mechanisms corresponding to the interchange of the P- and T-axes and a roation of the mechanism by 180 degrees. To select one mechanism, P-wave first motion can be used. This was not possible in this case because all the P-wave first motions were emergent ( a feature of the P-wave wave takeoff angle, the station location and the mechanism). The other way to select among the mechanisms is to compute forward synthetics and compare the observed and predicted waveforms.

The velocity model used for the waveform fit is a modified Utah model .

The fits to the waveforms with the given mechanism are show below:

This figure shows the fit to the three components of motion (Z - vertical, R-radial and T - transverse). For each station and component, the observed traces is shown in red and the model predicted trace in blue. The traces represent filtered ground velocity in units of meters/sec (the peak value is printed adjacent to each trace; each pair of traces to plotted to the same scale to emphasize the difference in levels). Both synthetic and observed traces have been filtered using the SAC commands:

hp c 0.02 3
lp c 0.05 3

Discussion

The Future

Should the national backbone of the USGS Advanced National Seismic System (ANSS) be implemented with an interstation separation of 300 km, it is very likely that an earthquake such as this would have been recorded at distances on the order of 100-200 km. This means that the closest station would have information on source depth and mechanism that was lacking here.

Acknowledgements

Dr. Harley Benz, USGS, provided the USGS USNSN digital data.

Appendix A

The figures below show the observed spectral amplitudes (units of cm-sec) at each station and the theoretical predictions as a function of period for the mechanism given above. The modified Utah model earth model was used to define the Green's functions. For each station, the Love and Rayleigh wave spectrail amplitudes are plotted with the same scaling so that one can get a sense fo the effects of the effects of the focal mechanism and depth on the excitation of each.

Quality Control

Here we tabulate the reasons for not using certain digital data sets

DUG, HAWA had gains too low. MNV had data dropouts, HAWA seemed to have gains slightly too low.

The following stations did not have a valid response files:

Last Changed Thu Nov 18 16:01:10 CST 2004