SIUC - STATION INSTRUMENTATION
1. Cooperative New Madrid Seismic Network: [ NM ]
DATES OF OPERATION: 1999 day 56 to Present
SEISMOMETER TYPE and ADC:
Guralp CMG-40T from 1999,056,21:00:00.0000 to 1999,111,14:28:00.0000
Guralp CMG-3ESP from 1999,111,14:28:00.0000 to present
a Kimemetrics Episensor was added 2004,174,14:54:00.0000 to present
ADC is Quanterra Model Q-380 from 1999,056,21:00:00.0000 to 2004,174,14:54:00.0000
ADC is Quanterra Model Q-330 from 2004,174,14:54:00.0000 to present
DIGITAL FORMAT:
24 bit integer data words for all broadband (20 sps), long period (1 sps) and
triggered (80 sps).
From 1999,056,21:00:00.0000 to 2004,174,14:54:00.0000
24 bit integer data words for all broadband (100, 40 sps), long period (1 sps).
From 2004,174,14:54:00.0000 to present
Range: +8,388,607 to -8,388,608 counts.
EVENT DETECTOR ALGORITHM:
The Murdock event detector (Murdock, 1991) is used for all short period channels.
From 2004,174,14:54:00.0000 on, the data is recorded continuously.
Click on any of the following items for further information.
COMMENTS:
The three minute long, every 15 minutes or so noise is caused by a
large air compressor in the building attic.
Last Changed October 11, 2004